Free 1-3 Days shipping in the UK Mainland for all products Over £150 - Under 20KG

Newest Products

4867 products

  • Last stock! Autotransformer 120/240V-100A

    Victron Autotransformer 120/240V-100A

    4 in stock

    An autotransformer can be used for step up, step down and split phase output balancing purposes. While the step up and step down functions are fairly straightforward, split phase output balancing may require some more attention. The Autotransformer: for a step up, step down and split phase balancing  An autotransformer can be used for step-up, step down and split phase output balancing purposes. While the step up and step down functions are fairly straightforward, split phase output balancing may require some more attention.  Consider for example a 30A 120/240V split phase supply. The supply could be the grid, a generator or two stacked inverters. Some of the loads connected are 240V, others are 120V. On each 120V leg the load should not exceed 30A. The problem is that as soon as 120V loads are connected, the two legs will show a different current. This is because the 120V loads on the two legs will never be balanced. A 120V 1200W hairdryer, for example, will draw 10A from one leg. A 120V washing machine could even draw in excess of 20A from one leg. Between the two legs the difference in current, or current unbalance, will therefore often be 20A or more. This means that the 30A supply will not be used up to its full potential. By the time one leg draws 30A, the other leg may be drawing no more than 10A, and increasing the 240V load, for example, will result in an overload of one leg while the other leg still has spare capacity.  Theoretically, the total power that can be drawn from a 30A 120/240V supply is 30 x 240 = 7,2 kVA. In case of 20A unbalance, the practical maximum will be 30 x 120 + 10 x120 = 4,8kVA, or 67% of the theoretical maximum.  The solution is an Autotransformer. By leaving the neutral of the split phase supply unused, and connecting an Autotransformer to create a new neutral, as shown in figure 1, any load unbalance is ‘absorbed’ by the Autotransformer. In case of a 30A supply, the load can be increased to 7,2kVA, and a 20A load unbalance will result in one leg supplying 40A, and the other leg 20A. The 20A difference will flow through the neutral and the windings of the Autotransformer. The current through both 120V wires of the split phase supply will be 30A.  Pdf

    4 in stock

    £754.33

  • Last stock! Autotransformer 120/240V-32A

    Victron Autotransformer 120/240V-32A

    4 in stock

    An autotransformer can be used for step up, step down and split phase output balancing purposes. While the step up and step down functions are fairly straightforward, split phase output balancing may require some more attention. The Autotransformer: for a step up, step down and split phase balancing  An autotransformer can be used for step-up, step down and split phase output balancing purposes. While the step up and step down functions are fairly straightforward, split phase output balancing may require some more attention.  Consider for example a 30A 120/240V split phase supply. The supply could be the grid, a generator or two stacked inverters. Some of the loads connected are 240V, others are 120V. On each 120V leg the load should not exceed 30A. The problem is that as soon as 120V loads are connected, the two legs will show a different current. This is because the 120V loads on the two legs will never be balanced. A 120V 1200W hairdryer, for example, will draw 10A from one leg. A 120V washing machine could even draw in excess of 20A from one leg. Between the two legs the difference in current, or current unbalance, will therefore often be 20A or more. This means that the 30A supply will not be used up to its full potential. By the time one leg draws 30A, the other leg may be drawing no more than 10A, and increasing the 240V load, for example, will result in an overload of one leg while the other leg still has spare capacity.  Theoretically, the total power that can be drawn from a 30A 120/240V supply is 30 x 240 = 7,2 kVA. In case of 20A unbalance, the practical maximum will be 30 x 120 + 10 x120 = 4,8kVA, or 67% of the theoretical maximum.  The solution is an Autotransformer. By leaving the neutral of the split phase supply unused, and connecting an Autotransformer to create a new neutral, as shown in figure 1, any load unbalance is ‘absorbed’ by the Autotransformer. In case of a 30A supply, the load can be increased to 7,2kVA, and a 20A load unbalance will result in one leg supplying 40A, and the other leg 20A. The 20A difference will flow through the neutral and the windings of the Autotransformer. The current through both 120V wires of the split phase supply will be 30A.  Pdf

    4 in stock

    £696.95

  • Last stock! Ignition Electrode Kit Trumatic C (34020-00242)

    Truma Ignition Electrode Kit Trumatic C (34020-00242)

    5 in stock

    Ignition electrode kit for Trumatic C. Comprises: Set of spark plugs, screws and seals. Brand Truma Type Electrodes

    5 in stock

    £133.11

  • Last stock! Trumatic Thermocouple 25cm

    Truma Trumatic Thermocouple 25cm

    4 in stock

    Trumatic thermocouple 25cm. S2200, S3002 (04/93 on), S5002 (05/93 on) Brand Truma Type Thermocouples

    4 in stock

    £49.65

  • Last stock! Truma Ultrastore Non Return Valve

    Truma Truma Ultrastore Non Return Valve

    3 in stock

    Truma water heater non-return valve. Ultrastore / Boiler Series 3 (07/93 onwards), Ultrastore Rapid GE, Boat Boiler Series 2 (06/96 to 06/02), Boat Boiler Series 3 (07/02 onwards), Electro boiler (05/04 onwards). (70000-03300) Brand Truma Type Valves

    3 in stock

    £8.08

  • Truma Ultrastore Cowl Cover KBS 2 Cream

    Truma Truma Ultrastore Cowl Cover KBS 2 Cream

    12 in stock

    Truma water heater cowl cover KBS 3, White. Ultrastore / Boiler Series 3 (From 07/06). (70122-01) Brand Truma Type Flue Cowls

    12 in stock

    £51.80

  • Truma Ultrastore Cowl Cover KBS 3 White

    Truma Truma Ultrastore Cowl Cover KBS 3 White

    90 in stock

    Truma water heater cowl cover KBS 3, White. Ultrastore / Boiler Series 3 (From 07/06). (70122-01) Brand Truma Type Flue Cowls

    90 in stock

    £25.91

  • Truma Ultrastore 3 Complete Cowl White

    Truma Truma Ultrastore 3 Complete Cowl White

    31 in stock

    This kit contains the outer grill, cover and plate for the Truma Ultrastore 3. Brand Truma Type Flue Cowls

    31 in stock

    £64.77

  • Truma Ultraflow O-Ring

    Truma Truma Ultraflow O-Ring

    28 in stock

    Truma Ultraflow O Ring

    28 in stock

    £6.34

  • Last stock! Truma Pistol Connection Complete

    Truma Truma Pistol Connection Complete

    2 in stock

    Truma Ultraflow pistol housing complete. (40060-97700)

    2 in stock

    £71.22

  • Last stock! Truma Flexible Elbow Fitting 2

    Truma Truma Flexible Elbow Fitting 2

    5 in stock

    Truma elbow fitting with connector for flexible water hose 10mm with breather tube. (34150-01)

    5 in stock

    £15.11

  • Last stock! Truma Elbow Fitting 12mm (34151-03)

    Truma Truma Elbow Fitting 12mm (34151-03)

    5 in stock

    Truma Ultraflow adapter, John Guest Speedfit to flexible hose. Must be used to connect flexible hoses to the surge damper. (40060-99900)

    5 in stock

    £18.36

Login

Forgot your password?

Don't have an account yet?
Create account